Nortel Networks 553-3901-200 Network Card User Manual


 
Page 22 of 46 Install ISDN BRI hardware
553-3901-200 Standard 7.00 January 2002
5 Push the tabs firmly against the front panel of the card so they latch to
the front lip in the module and to the post on the card.
6 Observe the red LED located on the faceplate.
If the red LED turns on and stays lit continuously, the card is
defective. Remove the card, choose a new card, and repeat
the installation procedure.
If it flashes three times and then turns off, the card is operating
correctly. Go to step 7.
If the red LED flashes three times and then stays lit
continuously, the card is operating correctly but is not
configured. Go to step 7.
7 On the CE/PE or IPE Module Card Location Form, fill in the card type
and the module number next to the slot number of the installed card.
8 Repeat steps 1 through 7 for each card requiring installation.
—————————— End of Procedure ——————————
Remove the BRSC, SILC and UILC
1 Hold the card by its card-locking devices. Squeeze the tabs to unlatch
the card-locking devices and lift them away from the card.
2 Carefully disengage the BRSC, SILC or UILC from the backplane
connector, and slowly slide out the card from the module.
—————————— End of Procedure ——————————
Connect ISDN BRI terminals to Meridian 1
Connecting the ISDN BRI terminals to the Meridian 1 consists of the
following procedures.
connect the Meridian 1 to the Main Distribution Frame (MDF)
cross connect the MDF
connect the ISDN BRI terminals to the DSL
Figure 5 shows a typical DSL with ISDN BRI terminals connected to it using
modular cables.