Nortel Networks 2700 Network Card User Manual


 
Appendix A Technical specifications 97
Nortel VPN Router Installation — VPN Router 2700
You need a DSU/CSU (digital service unit/channel service unit) between the
WAN connection and the gateway. You can order a V.35 or X.21 cable to attach to
the connector. With this cable, the WAN adapter can function as DTE (data
terminal equipment).
Table 32 provides the V.35 cable pinouts. Table 33 on page 98 provides the X.21
cable pinouts. (The pair suffix A or B refers to an individual wire within a twisted
pair.)
Table 32 V.35 cable pinouts
Standard-wired
end 28-pin male Signal name
Pair number
and conductor
Special-wired
end 34-pin male Notes
2 TXDA pair 1A P
14 TXDB pair 1B S
3 RXDA pair 2A R
16 RXDB pair 2B T
15 TXCA pair 3A Y
12 TXCB pair 3B AA
17 RXCA pair 4A V
9 RXCB pair 4B X
24 SCTEA pair 5A U
11 SCTEB pair 5B W
4 RTSA pair 6A C
19 RTSB pair 6B no conn Note 1
5 CTSA pair 7A D
13 CTSB pair 7B no conn Note 1
6 DSRA pair 8A E
22 DSRB pair 8B J
20 DTRA pair 9A H
23 DTRB pair 9B no conn Note 1
8 DCDA pair 10A F
10 DCDB pair 10B no conn Note 1
18 LL pair 11A L
21 RL pair 11B N