Nortel Networks R2MFC Network Card User Manual


 
44 Chapter 4 Configuring the R2MFC card
N0087114 1.0
5 Press .
The display shows Card on KSU.
6 Press .
The display shows Cd1-KSU.
7 Press until the display shows the card you want to view (CD1 — the right most
DTI card).
8 Press CHANGE to view the different cards: Loop, T1, PRI, BRI-U4, BRI-U2 or
BRI-ST.
9 Select PRI and press .
The display shows Clear line data.
10 Select Y (yes) to confirm your selection.
11 Press .
The display shows Lines 001-030.
12 Press .
The display shows BchanSeq.
You must choose the opposite setting of your service provider. However, if all lines for two
DTI cards (configured as PRI) are in the same PRI pool, then you must set both cards to use
the descending B-channel sequence mode. As a result, the service provider must use ascending
mode.
13 Press CHANGE to select either ascending or descending.
14 Press .
The display shows CRC4.
15 Press CHANGE to select OFF.
16 Press .
The display shows ClockSrc.
17 Press CHANGE to toggle the setting (Primary).
18 Press .
The display shows Ovlap recving.
19 Press CHANGE to select Y.
20 Press
.
The display shows Lol num len.
Note: You cannot change this setting unless you first disable the Trunk
Cartridge using Module Status in Maintenance. Remember to enable the
Trunk Cartridge once you complete the programing.