Nortel Networks R2MFC Network Card User Manual


 
60 Chapter 6 Command Line Interface (CLI)
N0087114 1.0
Accessing the CLI
The CLI is accessed through the RS-232 port on the faceplate of the R2MFC card. The cable that
was shipped with the R2MFC card, part number N0026100, is used to connect a computer to the
R2MFC card.
Perform the following steps to access the CLI:
1 Use the shipped cable to connect a PC to the RS-232 port on the faceplate of the R2MFC card
through COM1.
2 Open a Hyper-terminal session on the PC using the following parameters:
3 Wait for monitor line (flashing cursor) to appear on the terminal session.
4 Switch to appropriate user by using the
su command and entering the appropriate username
and password.
5 Access the desired directory using the directory commands listed in this chapter.
6 Execute any desired commands.
7 Release the COM port by closing the Hyper-terminal session.
8 Remove the cable connecting the PC to the R2MFC card.
Table 14 Hyper-terminal setup parameters
Parameter Setting
Connect using COM 1 or COM 2
Bits per second 19 200
Data bits 8
Parity None
Stop Bits 1
Flow Control None