Nortel Networks R2MFC Network Card User Manual


 
70 Chapter 6 Command Line Interface (CLI)
N0087114 1.0
MFC directory
Table 22 includes the CLI commands for the configuration and control of MFC-R2 protocols. The
commands are accessed from the MFC directory.
Table 22 MFC directory CLI commands (Sheet 1 of 3)
CLI command Description
ICm <mfc_link>
<incoming_timer_type> <msec>
Sets and displays incoming call timers.
Where:
mfc_link is the number of required mfc/r2 links.
incoming_timer_type is one of the timers defined for incoming mfc call
processing.
msec is the time interval in msec.
OGm <mfc_link>
<outgoing_timer_type> <msec>
Sets and displays outgoing call timers.
Where:
mfc_link is the number of required mfc/r2 links.
outgoing_timer_type is one of the timers defined for outgoing mfc call
processing.
msec is the time interval in msec.
REgSign <mfc_link><rs_name> Sets the register signaling
Where:
mfc_link is the number of the link, 0 or 1.
rs_name is the signaling type, 0 (MFC) or 1 (SMFC).
AniOption <mfc_link><flag> Enables or disables the ANI option.
Where:
mfc_link is the number of the link, 0 or 1.
flag defines the ANI option as enabled (0) or disabled (1).
When disabled, ANI is not requested in incoming calls and not transmitted in
outgoing calls.
mfcINDia<flag> Enables or disables the processing of the special MFC option for India.
Where:
flag defines the Special ANI digit option as enabled (0) or disabled (1).
When enabled, the prefix of one is expected on incoming calls and is
transmitted on outgoing calls.