Olivetti 4501 Copier User Manual


 
SADDLE STITCH FINISHER
3-19
3
Staple cartridge replacement and staple jam removal
When the staple cartridge becomes empty or staples become jammed, a message will appear in the message
display of the operation panel.
Follow the procedure below to replace the staple cartridge or remove jammed staples.
Staple cartridge replacement
1
Open the front cover.
2
Pull out the stapler section.
3
Turn roller rotating knob A in the direction
of the arrow to move the staple unit to the
front.
Turn the roller rotating
knob until the triangle
mark is aligned with the
index.
4
Remove the empty staple box.
5
Remove the empty staple cartridge.
Press the lock button to
unlock the staple box
cover and remove the
staple cartridge.
6
Insert a new staple cartridge into the
staple box.
After inserting the staple
cartridge, press down on
the staple box cover to
lock the cartridge in
place.
7
Remove the tape from the staple cartridge
by pulling it straight.
8
Insert the staple box.
Push the staple box in
until it clicks into place.
9
Push the stapler section back into the
finisher.
10
Close the front cover.
NOTE
If staples remain, the staple cartridge cannot be
removed.
Roller rotating
Staple unit
knob A
NOTES
Do not remove the tape from the cartridge before
inserting the staple cartridge into the box.
Make sure that the staple cartridge is secured
firmly.
When reinstalling the staple box, push it in until it
clicks into plac
e.
NOTE
Make a test print or copy in the staple sort mode to
ensure that stapling is performed properly.