Output Solutions PS40T Printer User Manual


 
37
Setup Parameter Values Description
INTERFACE TYPE parallel, serial, automatic,
auto+blink
Selects the interface type. In case of ‘automatic’ the
interface type is selected by the printer depending on data
coming from host. When the
auto+blink
item is selected,
the P1 and P2 leds blink to indicate which interface is
selected: P1 blinks when the serial interface is selected,
whereas P2 blinks when the parallel interface is selected.
INPUT BUFFER 1 Kb, 8 Kb, 16 Kb, 32 Kb Selects the buffer size.
IGNORE PE enabled, disabled Selects whether the printer signals the paper empty
condition (
disabled
) or not (
enabled
).
AUTOFEED
SIGNAL
disabled, enabled The parallel interface uses (
enabled
) or does not use
(
disabled
) the AUTOFEED signal.
SLCT-IN SIGNAL disabled, enabled The parallel interface uses (
enabled
) or does not use
(
disabled
) the SELECT-IN signal.
BUFFER
CONTROL
DTR+SRTS, SRTS,
XON/XOFF,
XON/XOFF+DTR+SRTS
Selection of the buffer protocol.
ROBUST XON enabled, disabled Perform the Robust XON (
enabled
) or not (
disabled
).
WORD LENGTH 7 bit, 8 bit Sets the number of the data bits.
BAUD RATE 600 - 38400 bps Sets the data transfer rate.
PARITY BIT Even, odd, none Selects the parity control for the data.
SECURITY MODE enabled, disabled Enables or disables the security actions that assure
protection against paper jams. If disabled, the paper