4. Input/output signal settings
4-1. Setting the SDI input signals and analogue input signals
The user can set the SDI input signals and analogue input signals.
IN5 to IN8 can be set only when one of the following optional boards has been connected:
SDI input board
Analogue input board
Analogue composite input board
4-1-1. Setting the frame synchronizer
The frame synchronizer can be set to On or Off for each input.
The DVI input (option) frame synchronizer is permanently On. It cannot be set from On to Off or vice versa.
1
Press the [FUNC] button to light its indicator, and press the [IN/OUT] button to display the IN/OUT menu.
2 T
urn [F1] to display the Input sub menu.
3
Turn [F2], select the input signals using the Signal item, turn [F3], and select On or Off for the frame
synchronizer using the FS item.
If the output signal phase is set to 0H, Off cannot be selected as the FS item setting.
<Menu display>
Input Signal FS Mode AnaGain
1/15 In1 On
Normal 0
IN1-8
Off D by D
UC
Auto
−30-+30
AVDL function is active while the frame synchronizer function is set to Off.
The AVDL function automatically adjusts the input image signal phase to the horizontal synchronization
reference signal phase.