181
[Reference]
Reference
Peripheral Equipment
Environment
The servo driver should be used under Contamination Level 2 or 1 specified by IEC60664-1 (housing the driver in
an IP54 control box).
Control box
Controller
Power supply for
insulated type
interface
Power
Insulating
transformer
Circuit
breaker
Leakage
breaker(RCD)
Surge
absorber
Noise filter
Noise filter for
signal lines
Protective earth (PE)
L1
U
CN X5
CN X1
CN
X3
CN X4
M
RE
V
W
E
L2
L3
Noise filter for
signal lines
AC servo
driver
AC servo
driver
Power
Single-phase 100V: Single-phase 100V to 115V 50/60Hz
Single-phase 200V: Single-phase 200V to 240V 50/60Hz
Three-phase 200V: Three-phase 200V to 240V 50/60Hz
(1) Use under the environment of Over-voltage Category II specified by IEC60664-1
In order to realize the environment of overvoltage category II, install in the power supply input unit an insulating
transformer that is compliant with ICE or EN standard (EN 60742).
(2) The power for interface should be marked CE or appropriate EN Standard type (EN60950), 12VDC to 24VDC,
insulated.
Circuit Breaker
Install a circuit breaker between the power supply and noise filter. The circuit breaker should be IEC Standard and
UL listed marked.
+ 10%
- 15 %
+ 10%
- 15 %
+ 10%
- 15 %
+ 10%
- 15 %
+ 10%
- 15 %
+ 10%
- 15 %