![](http://pdfasset.owneriq.net/1/97/19735130-24f3-4e5c-a30d-40752499fb3c/19735130-24f3-4e5c-a30d-40752499fb3c-bg2a.png)
196
Dimensional Outline Drawing
LR
LR/2
P
A
M
B
Radial Load Direction (P)
Thrust Load Directions (A, B)
Motor
Series
MUMA
When Assembled In Operation
Radial Load
147
392
Thrust Load
Direction A
88.2
147
Direction B
117.6
196
Radial Load
68.6
245
Thrust Load
Directions A, B
58.8
98
Motor Output
50W, 100W
200W, 400W
Unit: N (1kgf = 9.8N)
L
P
<Remarks>
If a position of load point varies, calculate allowable radial load P (N) from distance L (mm) of a load point
from mounting flange face, based on the relational expression, so that the result of calculation will be as
follows:
Motor
Series
Motor Output
Relational Expression
of Load - Load Point
MUMA
50W, 100W
200W
400W
1406
P =
L + 7.5
2940
P =
L – 3
5831
P =
L + 8.8
Allowable Load of Output Shaft