163
[Reference]
Reference
Example of Data Communication
Example of Changing Parameters
The following illustrates time-series communications data flow when a change is made to a parameter.
Communications should be conducted in the sequence of outline, (1) individual writing of parameters and (2) writing
to EEPROM if storage is needed. In this example of hardware connection, the device is directly connected with a
host through RS232C communications with user ID=1. Data is represented in hexadecimals.
(Note) For details of commands, refer to “List of Communications Commands” on Page 166.
(1) Individual Writing of Parameters
(2) Writing of Parameters to EEPROM
Host
04 06
(EOT) (ACK)
05 03 01 18 0B 00 00 D9
(ENQ)
(ACK) (ENQ)
MINAS-E(
1)
Host
05 01 01 18 00 E6 04
(ENQ) (EOT)
04 06 05 00 01 48
(EOT) (ACK) (ENQ)
MINAS-E(
1)
Host
06 05 01 01 48 00 B6
B7 04 06
(EOT) (ACK)
MINAS-E(