Deactivating the Alarm Relay for Carrier-Mounted DSU/CSUs
The Alarm Cut-off command forces a deactivation of the alarm relay on the
3000 Series Carrier during an alarm condition. Since this function only affects the
3000 Series Carrier, it is only available for carrier-mounted DSU/CSUs. The alarm
relay function must first be enabled by the Alarm Relay configuration option (refer
to Appendix C,
Configuration Options
).
Procedure
To deactivate the alarm relay:
1. From the top-level menu screen, press the key until the Ctrl selection
appears on the screen.
2. Select Ctrl.
3. From the Control screen, select ACO.
4. The Command Complete screen appears.
F1
F2
F3
Control:
ACO Rel LED
F1
F2 F3
Alarm Cut-Off:
Command Complete