Paradyne 916x Network Card User Manual


 
Menus and Configuration Worksheets
A-12
9161-A2-GH30-30April 1998
Device Name: ___________________________________________________________
User Interface
Configuration Option Settings
Default in
[Bold]
Communication Port See Table 5-10
Port Use [Terminal], Net Link, Alarm
Port Type [Asynchronous], Synchronous
RIP
1
[None], Proprietary
Port Type – Synchronous
Clock Source [Internal], External
Data Rate (Kbps)
2
9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2
Port Type – Asynchronous
Data Rate (Kbps) 9.6, 14.4, [19.2], 28.8, 38.4 57.6, 115.2
Character Length
3
7, [8]
Parity
3
[None], Even, Odd
Stop Bits
3
[1], 1.5 ,2
Ignore Control Leads
3
[Disable], DTR
Login Required
4
Enable, [Disable]
Port Access Level
4
[Level-1], Level-2, Level-3
Inactivity Timeout
4
Enable, [Disable]
Disconnect Time (Minutes)
4,5
1 – 60 [5]
External Device (COM Port) See Table 5-11
External Device Commands [Disable], AT, Other
Dial-In Access
6
Enable, [Disable]
Connect Prefix
7
ASCII text entry, Clear
Connect Indication String
7
ASCII text entry, Clear
Escape Sequence
7
ASCII text entry, Clear
Escape Sequence Delay (Sec)
7
[None], 0.2, 0.4, 0.6, 0.8, 1.0
Disconnect String
7
ASCII text entry, Clear
1
Only shown when Port Use is set to Net Link.
2
Only shown when Clock Source is set to Internal.
3
Only shown when Port Type is set to Asynchronous.
4
Only shown when Port Use is set to Terminal.
5
Only shown when Inactivity Timeout is set to Enable.
6
Only shown when External Device Commands is set to Other or AT.
7
Only shown when External Device Commands is set to Other.