Philips 27964-01A Projector User Manual


 
are and Maintenance
27964-01A
20
Cleaning After Use
Clean and disinfect your tanning bed’s
bench and canopy after each use. Use a
non-abrasive disinfectant cleaner that does
not contain ammonia or ammonia deriva-
tives. Ammonia may damage the acrylic
shield. Spray the acrylic lightly with disin-
fectant and wipe dry with a clean soft cloth.
We recommend Australian Gold® pH
Neutral Disinfectant Cleaner.
Thorough Periodic Cleaning
Introduction
The cooling fans draw air through the bed
and over time will cause a dust buildup on
the lamps and reflectors. This will reduce
the tanning effectiveness of the bed. When
a dust buildup is observed, it is necessary to
thoroughly clean the inside of the bench
and canopy.
Cleaning the Canopy and Bench
Step 1 Remove the acrylic shields and
lamps as described in Lamp and
Acrylic Replacement.
Step 2 With a soft cloth, wipe the entire
length of each lamp to remove
any film buildup.
Step 3 Clean both sides of the acrylic
shields with a non-ammonia dis-
infectant cleaner.
Step 4 Wipe the reflectors with a clean
damp cloth.
Step 5 Re-install the lamps and acrylic
shields.
Mechanical Inspection
Your tanning bed has been built for years of
service. To ensure trouble-free operation
throughout its life, inspect the unit’s
mechanical integrity every 400-500 hours
of use.
Inspect the unit’s fasteners verifying
that all are firmly in place.
Inspect gas springs for signs of wear.
Gas springs that will not hold the
canopy in the full open position when
raised should be immediately replaced.
See Troubleshooting.
Inspect the AC power cord and its
connections.
Inspect the acrylic. Broken, cracked
or
badly scratched acrylics should be
immediately replaced.
WARNING
Shock hazard.
Disconnect power before removing
any protective covers.