Troubleshooting
Problem Solution
Timer display is indicating Er 91
Timer display is indicating Er 92
Timer display is indicating Er 93
Timer display is indicating Er 94
Timer display changes to indicate
a tanning time after the timer but-
ton is pressed but lamps do not
come on
My bed is connected to the T-
Max® Manager remote system
and when the delay time has
expired the timer display starts
counting down but the bed lights
do not come on
My bed won’t work with the T-
Max® Manager remote system
Timer display continues to show a
0 after the timer button is pressed
Timer software error. Disconnect and reapply power to the unit.
Current sensor indicating unit is off when it should be on.
Contact servicer.
Current sensor indicating unit is on when it should be off.
Contact servicer.
Requested session time exceeds maximum time allowed.
1. Bypass plug is not installed, see Electrical Connections.
2. A non-SunStar® bypass has been used. See Electrical
Connections.
3. If remote is being used, other than T-Max® Manager, the exter-
nal timer may not be activated.
4. Remote wiring is incorrect, see the instructions provided with
the remote interface kit.
The auto start feature of the remote system is disabled, see the
instructions provided with your remote system.
1. The sunbed must first be set to a unique address, see Remote
Connections.
2. The bypass or terminator plug may be installed in the series in
an inappropriate location. Plug the bypass plug only into the
bed at the end of the series.
1. T-Max® Manager remote system has not yet been set.
2. Sunbed address is not set correctly, see Remote Connections.