Planet Technology WGSD-8000 Switch User Manual


 
User’s Manual of WGSD-1022/WGSD-8000
- 278 –
period seconds — Specifies the requested period time to display. (Range: 1 - 4294967295)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example displays RMON Ethernet Statistics history for "throughput" on index number 5.
Console# show rmon history 5 throughput
Sample Set: 1 Owner: CLI
Interface: g1 Interval: 1800
Requested samples: 50 Granted samples: 50
Maximum table size: 500
Time Octets Packets Broadcast Multicast %
----------------------------- ------------- -------------- ----------------- --------- ------
Jan 18 2002 21:57:00 303595962 357568 3289 7287 19.98%
Jan 18 2002 21:57:30 287696304 275686 2789 2789 20.17%
The following example displays RMON Ethernet Statistics history for "errors" on index number 5.
Console# show rmon history 5 errors
Sample Set: 1 Owner: CLI
Interface: 1/g1 Interval: 1800
Requested samples: 50 Granted samples: 50
Maximum table size: 500
Time CRC Align Undersize Oversize Fragments Jabbers
------------------------------ --------------- ---------------- ------------- --------------- -------------
Jan 18 2002 21:57:00 1 1 49 0 0
Jan 18 2002 21:57:30 1 1 27 0 0