Q-Logic 3000 Switch User Manual


 
1–Switch Management Classes
QLGC_LogicalIOBlade : CIM_LogicalIOBlade
1-20 59223-03 E
And optionally, one of the following enumerated state values.
08-Starting: Blade has been inserted, or enabled.
09-Stopping: Blade has been turned off, and is shutting down.
10-Stopped: Blade has been turned off (presumably for
removal).
15-Dormant: Blade has been disabled.
11-InService: The Blade is in diagnostic mode
A healthy blade working normally will report the array [02] for this
property.
HealthState
This property will report the diagnostic status of the blade as a result of
the Switch POST. Supported values are:
0 – Unknown Blade is not installed
5 – OK No errors
10 – Degraded Blade operation is compromised.
25 – Critical Failure Blade failed POST
ModuleNumber
Property will contain the zero based blade index. A blade is uniquely
identified by the combination of the Blade Type and the blade (Module)
number.
LogicalModuleType
Property will contain the enumerated value 4=Blade.
EnabledState
Property will contain the current blade enabled state.
02-Enabled: Blade is enabled
03-Disabled: Blade is disabled (all ports disabled)
07-InTest: Port is in diagnostic mode
RequestedState
Property will contain the value 5=No Change. All blade state changes
are atomic, so there will never be a pending requested state.
EnabledDefault
Property will contain the configured blade state.
02-Enabled: Blade is enabled
03-Disabled: Blade is disabled
RequestStateChange
Method will change the configured blade state to the RequestedState
value. If the RequestedState parameter is 11-Reset, the blade will be
reset, but the configured state will not change.