5 – Diagnostics/Troubleshooting
POST Diagnostics
5-2 59042-01 A
5.1.1.2
Force PROM Mode Pattern
Steady illumination indicates that the switch is in force PROM mode, which returns
the switch IP address to 10.0.0.1. From force PROM mode, you may reload
firmware, reset the password to the factory default, and remove a corrupt
configuration.
5.1.1.3
Internal Firmware Failure Blink Pattern
An internal firmware failure blink pattern is 2 blinks per second followed by a two
second pause. The 2-blink error pattern indicates that the firmware has failed, and
that the switch must be reset.
5.1.1.4
Fatal Error Blink Pattern
A fatal error blink pattern is 3 blinks per second followed by a two second pause.
The 3-blink error pattern indicates that a fatal error has left the switch inoperable.
If a fatal error occurs, contact your authorized maintenance provider.
5.1.1.5
Configuration File System Error Blink Pattern
A configuration file system error blink pattern is 4 blinks per second followed by a
two second pause. The 4-blink error pattern indicates that a configuration file
system error has occurred, and that the configuration file must be recreated.
To recreate the configuration file, do the following:
1. Place the switch in force PROM mode by pressing and holding the
Reset/Force PROM button. Refer to ”Recovering a Switch” on page 5-9 for
more information about placing the switch in force PROM mode.
2 seconds
1 second
2 seconds
1 second
2 seconds
1 second