RAD Data comm IPmux-1 Network Card User Manual


 
Appendix E Parameters and Screens IPmux-1/1E Installation and Operation Manual
E-16 IPmux-1 E1/T1 Configuration
Table E-11. E1 Physical Layer Configuration Parameters (Cont.)
Parameter Possible Values Remarks
Signaling mode
CAS enable
CAS disable
The E1 framer is set to CAS MF mode and the operation mode
to fractional with CAS mode.
CAS MF will not be set in the E1 framer and the operation
mode will be configured to fractional mode.
Note: This field will not appear if “unframed” is selected in the
Line Type field.
Default value: CAS Enable
Byte Code 00 to FF Conditioning pattern can be applied to timeslots toward the IP
path when loss of signal, loss of frame or AIS is detected at the
E1 line. Conditioning pattern can also be applied to timeslots
toward the E1 line when packet receive buffer overrun or
under-run occurs. In Unframed mode, conditioning state will
result in AIS transmission. This will be applied when a LOS is
detected at E1 line, or when packet receive buffer overrun or
under run occurs.
Note: This field will not appear if “unframed” is selected in the
Channel Type field.
Default Value: FF
4 bit code 1 to F The ABCD conditioning pattern can be applied toward the IP
path when loss of signal, loss of frame, or AIS is detected at the
E1 line. Conditioning pattern can also be applied toward the
E1 line when packet receive buffer overrun or underrun occur.
Note: This field will not appear if “Unframed” is selected in the
Channel Type field.
Default Value: 1