RAD Data comm IPmux-1 Network Card User Manual


 
IPmux-1/1E Installation and Operation Manual Appendix E Parameters and Screens
Performance Monitoring E-33
Analog Status – IPmux-1E with FXS
ANALOG STATUS
Channel 1: ON HOOK
Channel 2: ON HOOK
Channel 3: ON HOOK
Channel 4: ON HOOK
ESC. Exit
Figure E-31. Analog Status
The options for each channel are: On-hook, Off-hook, Ringing.
LAN Statistics (no User port)
LAN STATISTICS
Mac Address 00-20-D2-16-3B-3D
Mode Half duplex
Rate(Mbps) 10
Status Not connected
Frames received from the user
Correct frames: 0
Correct Octets: 0
Alignment Err: 0
FCS Errors: 0
Frames transmitted to the user
Correct frames: 0
Correct Octets: 0
Sngl Collision: 0
Mlty Collision: 0
Deferred transm: 0
Late Collision: 0
Carrier Sense: 0
Esc. Exit R. Reset Counters
Figure E-32. LAN Statistics Menu
LAN statistics are not collected in intervals.
Main Menu
3. Performance
Monitoring
2. LAN Statistics
Main Menu
3. Performance
Monitoring
1. Analog Status
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com