RAD Data comm IPmux-1 Network Card User Manual


 
Chapter 5 Application Configuration Procedures IPmux-1/1E Installation and Operation Manual
5-14 Configuring the Management Option
8. Press <Esc> a few times to return to the Main menu.
1. Remember to press <Enter> after modifying each parameter. Press <S> to
save all changes on the menu.
2. TDM Bytes in Frame and Jitter Buffer have been automatically set to default
values: 48 for TDM Bytes, 3 ms for Jitter Buffer.
BUNDLE CONNECTION CONFIGURATION
1. Bundle ID 32
2. Connection State Enable
3. Destination IP Address 192.168.10.1
4. Next Hop 0.0.0.0
5. Destination Bundle 1
6. Jitter Buffer(x10usec) 300
ESC. Exit D. Delete N. Next
Select item from the menu. Total used bundles: 1
Figure 5-7. Bundle Connection Configuration in IPmux-4
5.4 Configuring the Management Option
To configure this application for RADview or an SMNP management station
perform the following steps on each station of IPmux-1 and IPmux-4.
Authentication/Community
To configure Authentication/Community:
1. From the Management Configuration menu, press 1
Authentication/Community menu (see Figure 5-8).
2. Select Authentication Failure Trap and choose On.
3. Select Trap and choose Public.
4. Select Read and choose Public.
5. Select Write and choose Public.
6. Press <S> to save the configuration.
7. Press <Esc> to return to the Management Configuration menu.
Note
Main Menu
2. Configuration
1. General
Configuration
3. Management
Configuration
1.
Authentication/
Community