6.19 Stack Trace Function
The emulator uses the information on the stack to display the names of functions in the sequence
of calls that led to the function to which the program counter is currently pointing.
Note: This function can be used only when the load module that has the IEEE695-type
debugging information is loaded.
• Double-click the [S/W Breakpoints] column in the sort function and set a PC breakpoint.
Figure 6.39 [Source] Window (PC Breakpoint Setting)
• Set the same program counter value (PC = H’0E612) as was set in section 6.8, Setting
Registers (again, use the [Register] window). Click the [Go] button.
125