⎯ Variable updating
For updating of the content of the variable that has been registered in the [Watch] window,
read the data after the break in user program execution. The realtime operation for the user
program is disabled because the user program is temporarily stopped.
5. Line Assembly
⎯ Input radix
Regardless of the Radix setting, the default for line assembly input is decimal. Specify H’
or 0x for the H8 series microcomputers and xxxxh for the R8C/Tiny, M32C and M16C
series microcomputers as the radix for a hexadecimal input.
6. Command Line Interface
⎯ Batch file
To display the message “Not currently available” while executing a batch file, enter the
sleep command. Adjust the sleep time length which differs according to the operating
environment.
Example: To display “Not currently available” during memory_fill
execution:
sleep d’3000
memory_fill 0 ffff 0
⎯ File specification by commands
The current directory may be altered by file specifications in commands. It is
recommended to use absolute paths to specify the files in a command file so that the
current directory alteration is not affected.
Example: FILE_LOAD C:\Hew3\Tools\Renesas\DebugComp\Platform\E8\
E8R8C\TutorialR8C\Tutorial\Debug_R8C_E8_SYSTEM\Tutorial.x30
7. Memory Save During User Program Execution
Do not execute memory save or verifying during user program execution.
8. Load of Motorola S-type Files
This High-performance Embedded Workshop does not support Motorola S-type files with only
the CR code (H'0D) at the end of each record. Load Motorola S-type files with the CR and LF
codes (H'0D0A) at the end of each record.
9. [I/O] window
⎯ Display and modification
Do not change values in the [I/O] window because the emulator uses the address break
controller.
138
⎯ Note that the E8 emulator does not support the display of the invalid module in the [I/O]
window. For the H8/Tiny and H8/ Super Low Power series, the E8 emulator dose not
support the display of the bit information in the [I/O] window.