RobinAir AC1234-6 Tablet Accessory User Manual


 
16
Operating Instructions
Diagnostic Pressures
DiagnosticPressuresmodeisusedtocaptureand
printvehiclesystemoperatingpressures.Thefollowing
valuesareavailableforprinting:
vehicleinformation
systemhigh-sidepressure
systemlow-sidepressure
ambienttemperatureandhumidity
WhenDiagnosticPressuresmodeisselectedatthe
startofRECOVERYorAUTOMATICrecovery,the
valuesareavailableforprintinguntiltheendofthe
recovery.
Thecaptureofdiagnosticpressuresisrecommendedat
theendofCHARGEorAUTOMATICcharge.
WhenDiagnosticPressuresmodeisselected
fromMENU,valuesmaybeprintedaftercapturing
pressures.Themachinealsorequireshose
equalizationandhoseclear,necessarytoreduce
chargelossduetothediagnosticprocedure.
Printouts
At the End of Every Function
Dataforthefunctionjustcompletedmaybeprinted
fromtheresultsscreenbypressingOKonthe
machine’scontrolpanel.SeeFigure6.
After the Last Complete Service Mode
Asummaryofthecompleteservicemaybeprinted
fromSTORED DATAiftheVINwasenteredintothe
machinewhenprompted:
1.PressMENU onthemachine’scontrolpanel.
2.SelectFUNCTIONS.
3. ThechoicesunderSTORED DATA are:
PRINT DATA RECORD alistofVINsisdisplayed.
UsetheUPorDOWNarrowtohighlighttheVINfor
whichyouwishtoprintservicedata.
DELETE DATA RECORD followingtheprompts
forthisoptionpermanentlydeletesaVINandany
recordsassociatedwithit.
CLEAR ALL DATA followingthepromptsforthis
optionpermanentlydeletesallVINsandanyrecords
associatedwiththem.
Press OK to print data for
the function just completed.
Figure 6
Note:
Diagnostic pressures will be available
in Stored Data only when captured with
a VIN entry in Recovery, Automatic, or
Charge modes.
Diagnostic pressures captured from
MENU can be printed immediately after
the diagnostic pressures are taken, but
they will not be stored.
When running Diagnostic Pressures from
MENU, refrigerant identication occurs
before clearing hoses.