Sanyo VSP-9000 Network Card User Manual


 
English
Others 94
Appendix
b
bb
b SENSORMATIC
Code Function
RELAYS
0 All relays OFF
1 Relay 1 ON
2 Relay 2 ON
3 Relay 3 ON
4 Relay 4 ON
12 Relay 1 and 2 ON
13 Relay 1 and 3 ON
14 Relay 1 and 4 ON
23 Relay 2 and 3 ON
24 Relay 2 and 4 ON
34 Relay 3 and 4 ON
123 Relay 1, 2 and 3 ON
124 Relay 1, 2 and 4 ON
134 Relay 1, 3 and 4 ON
234 Relay 2, 3 and 4 ON
1234 Relay 1, 2, 3 and 4 ON
Example:
13: Makes only relays 1 and 3 valid (Relays 2 and 4 are invalid).
134: Makes only relays 1, 3 and 4 valid (Relay 2 is invalid).
PATTERN
51 Begins collection pattern 1.
52 Begins collection pattern 2.
53 Begins collection pattern 3.
55 Checks new pattern, and replaces the previous definition.
56 Ends pattern collection.
61 Begins pattern 1.
62 Begins pattern 2.
63 Begins pattern 3.
71 Deletes pattern 1.
72 Deletes pattern 2.
73 Deletes pattern 3.
Example:
Definition of Pattern 2:
72: Delete old pattern 2 (relates to apple-peel function)
52: Begins collection of pattern 2. The dome camera moves within the display
limits.
56: Ends collection.
55: Replaces old pattern with new record.
62: Begins pattern 2.
MISC.
9999 Initializes remote camera operation