Industrial Two of Five
Command Structure 1:3 ratio: B5bbccc (data)
2:5 ratio: BD5bbccc (data)
1:2 ratio: D5bbccc (data)
bb = Width of narrow element in dots (01-12)
ccc = Bar height in dots (001-600)
(data) = Bar code data (numeric); must be an even number of digits or
else the printer will add a leading zero
Character Set 0-9 (numeric only)
Notes To add horizontal guard bars to the top and bottom of the bar code,
use the Line and Box command (see Page 4-48).
Example
<ESC>H0100<ESC>V0600<ESC>BD50310012345
<ESC>H0300<ESC>V0710<ESC>XS12345
Appendix B: Bar Code Specifications
PageB-89001035Rev.ESATOCLSeriesPrinters