Enable Options
Command Structure <ESC>CLa
a = 0 Disable Dispenser Option
1 Enable Dispenser option
<ESC>CKa
a = 0 Disable Cutter Option
1 Enable cutter option
Example: <ESC>CL1
Placement: This command should be sendt in a separate data
stream.
Default: <ESC>CL0 (Dispenser Disabled)
<ESC>CK0 (Cutter Disabled)
Command Function To select the top-of-label sensing method.
Input to Printer
Printer Output Theres is no printer output as a result of this command.
Special Notes 1. The appropriate option must be installed before these commands
are effective.
2. Operation of the Dispenser and Cutter are dependent upon both
the <ESC>Q Quantity, the <ESC>CB Backfeed and the
<ESC>NULL (or <ESC>~) Cut commands.
Page 99 PN 9001092 Rev. A SATO CX208/212 Printers