SATO CX208/212 Printer User Manual


 
Auto-Calibrate
Command Structure <ESC>CFa
a = 0 Disable Auto-Calibrate
1 Enable Auto-Calibrate
Example: <ESC>CF1
Placement: This command should be sent in a separate data
stream.
Default: Enabled
Command Function To enable/disable the Auto-Calibrate function.
Input to Printer
Printer Output Theres is no printer output as a result of this command.
Special Notes 1. When Auto-Calibrate is enabled, the printer will automatically
attempt to calibrate when it detects an out-of-paper condition (10"
of platen feed after a label is printed without detecting a label edge
or sense mark). If the calibration is successful, the printer shall
move paper to the next index mark and resume normal
operations. If the calibration is not successful, the printer shall
indicate an out-of-paper condition by a red READY LED. The
printer shall restore the original index circuit settings.
2. See “Label Sensing” on page 8 for more information on
calibration.
Page 88 PN 9001092 Rev. A SATO CX208/212 Printers
CX208/212 Programming Guide