Expanded Memory Function
Graphics, Custom Store
Command Structure <ESC>GIabbbcccddd{data}
a = Specifies character format of the data
H Hex data
B Binary data
bbb = Number of horizontal8x8blocks (001 to104)
ccc = Number of vertical8x8blocks (001 to178)
ddd = Graphics storage number (001 to 099)
{data}= Hex or binary data to describe the graphic image
Example: See below.
Placement: Immediately following the <ESC>CC Memory Area
Select command.
Default: None
Command Function To provide similar functionality to the <ESC>G Custom Graphic
command, but allows for the graphic image to be stored in a
Expanded Memory. Use the Store command to send the graphic data
to the printer, which is held in the optional Expanded Memory, even if
printer power is lost.
Printer Input
Printer Output There is no printer output as a result of this command. See <ESC>GR
Recall Custom Graphics command.
Special Notes 1. You must have the optional Expanded Memory to use this
command. Call your SATO representative for details.
2. The maximum storage capacity is 999 graphics, up to the capacity
of the memory expansion.
3. Each graphic to be stored must be sent in its own data stream.
Page 75 PN 9001092 Rev. A SATO CX208/212 Printers
CX208/212 Programming Guide