SATO 410e Printer User Manual


 
Unit 3: Installation
SATO XL400-410e Operator Manual PN 9001135A Page 3-14
IEEE1284 PARALLEL INTERFACE
The parallel interface is a Plug-In, bi-directional, Interface Module that can be installed by the
user. It conforms to the IEEE1284 specification. It will automatically detect the IEEE1284 signals
and operate in the high speed mode. If it does not detect the IEEE1284 signals, it will operate in
the standard Centronics mode, which is significantly slower. For this reason, an interface cable
and host interface conforming to the IEEE1284 specification must be present to fully utilize the
speed capabilities.
Figure 3-6, Parallel Connector Pin Asignments
SPECIFICATIONS
Printer Connector AMP 57-40360 DDK (or equivalent)
Cable Connector AMP 57-30360 DDK (or equivalent)
Cable IEEE1284 Parallel, 10 ft. (3 m) or less
Signal Level High = +2.4V to +5.0V, Low = 0V to -0.4V
Data Stream <ESC>A . . Job#1 . . <ESC>Z<ESC>A . . Job#n . . <ESC>Z
IEEE 1284 PARALLEL INTERFACE PIN ASSIGNMENTS
PIN SIGNAL DIRECTION PIN SIGNAL DIRECTION
1 Strobe To Printer 19 Strobe Return Reference
2 Data 1 To Printer 20 Data 1 Return Reference
3 Data 2 To Printer 21 Data 2 Return Reference
4 Data 3 To Printer 22 Data 3 Return Reference
5 Data 4 To Printer 23 Data 4 Return Reference
6 Data 5 To Printer 24 Data 5 Return Reference
7 Data 6 To Printer 25 Data 6 Return Reference
8 Data 7 To Printer 26 Data 7 Return Reference
9 Data 8 To Printer 27 Data 8 Return Reference
10 ACK To Host 28 ACK Return Reference
11 Busy To Host 29 Busy Return Reference
12 Ptr Error To Host 30 PE Return Reference
13 Select To Host 31 INIT From Host
14 AutoFD1 To Host 32 Fault To Host
15 Not Used 33 Not Used
16 Logic Gnd 34 Not Used
17 FG Frame Gnd 35 Not Used
18 +5V (z=24k ohm) To Host 36 SelectIn1 From Host
1 Signals required for ieee 1284 mode.
1
19
18
36