Replacing Consumables and Maintenance Kit
22
1
U
Check the test sheets and select
the correction value for A through
H.
• Select "1", if black and magenta
square overlap sharply and
you can see white slits as the
sample.
• Select "0", if black and magenta
square do not overlap sharply
and you can not see white slits
clearly.
A B C D E F G H
0 0 0 0 0 0 0 0
Press {U
UU
U} or {T
TT
T} to select "0" or "1"
as the values for A - H. Press {En-
ter} to move to the next letter. After
setting the value for "H", press {En-
ter}, and the printer returns to the
ready condition.
Ready
Important
❒ If you select "0" for each alpha-
bets or an invalid value is select-
ed, an error message is
displayed. In this case, press
{Enter} to return to the ready
condition, and perform the
"Fuser Adjust" manually. See
P.35 “When replacing the fusing
unit”.
Invalid Value
Press #
❒ When "Toner is Almost Empty"
appears on the panel display,
replace the toner cartridge and
perform the "Auto Adjust", and
then perform "Fuser Adjust"
manually.
Reference
⇒ P.3 “Replacing the Toner Car-
tridge”
⇒ P.34 “Auto Adjust”
⇒ P.35 “When replacing the fus-