90
ITEM Mode Code & Hexadecimal n: (Hex.) = selection
[1] BAR CODE data DC4, DC4, B, n Specifies the numler ("n") of data to be regarded as
sequence 14, 14, 42, n bar code data.
0 <
n < 44H
[2] Check digit DC4, DC4, C, n Selects/deselects to add a check digit automatically.
14, 14, 43, n n: 00=No,
01=Yes.
[3] Element DC4, DC4, E, n1, n2 Changes the width of a bar, space, or intercharacter
variables 14, 14, 45, n1, n2 gap. n1 specifies the type of element and n2 sets
variable width in n2/120 inches.
This command is not effective in postnet bar code.
n1: 00=Narrow bar
01=Wide bar
02=Narrow space
03=Wide space
04=Intercharacter gap (ICG)
n2: n2/120" (1≤n2≤127)
[4] HRI font DC4, DC4, F, n Selects HRI character font.
14, 14, 46, n This command is not effective in postnet bar code.
n: 00=Current selected font
[5] Bar code height DC4, DC4, H, n Sets bar code height to n/12 inch (1≤n≤120).
14, 14, 48, n This command is not effective in postnet bar code.
If n≤4, HRI print is disabled.
[6] HRI print DC4, DC4, I, n Selects HRI character not to be printed or to be printed
14, 14, 49, n below or above bar code.
This command is not effective in postnet bar code.
n: 00=No print
01=Below bar code
02=Above bar code
[7] Bar code type DC4, DC4, T Selects a bar code type.
14, 14, 54, n n: 00=Industrial 2/5, n: 07=Code 128,
01=Interleave 2/5, 08=EAN 8,
02=Matrix 2/5, 09=EAN 13,
03=Codabar, 0A=UPC-A,
04=Code 11, 0B=UPC-E,
05=Code 39, 0C=Postnet
06=Code 93, FF=Element
[8] Guard bar DC4, DC4, G, n Euables/disables the guard bar extension (long bar).
extension 14, 14, 47, n in EAN and UPC.
n: 00=Disable guard bar extension
01=Enable guard bar extension (default)
[9] Start/stop char. DC4, DC4, N, n Assigns the start and stop character for the Codabar.
assignment 14, 14, 4E, n n: 00=Start character
01=Stop character
n: 02={"a", "b", "c", "d", "e", "t", "n", "*"}
Default is "a" as the start and stop character
[10] Start/stop char. DC4, DC4, S, n Selects to print the start and stop character as HRI for
print 14, 14, 53, n Codabar, Code 11, Code 39, and Code 93.
n: 00=To print(default)
01=Not to print
[11] Code 128 DC4, DC, V, n Selects code sequence in Code 128 to be treated as a
code sequence 14, 14, 56, n character value or as a character code.
n: 00=character code(default)
01=character value
[12] Bar code end ESC SO Indicates the end of bar code data sequence.
sequence 1B, 0E This sequence is valid when
#27 BAR CODE is to MODE2
in the SUB-MENU of SETUP MODE.
[13] Bar code start ESC SI Treats the following immediate data as a bar code.
sequence 1B, 0F This sequence is valid when
#27 BAR CODE is to MODE2
in the SUB-MENU of SETUP MODE.
B. Control code summary (bar code)