Sharp AR-161 Copier User Manual


 
2. Setting change procedure
Example: Changing the time for operating the auto clear function
(from 60 sec to 120 sec)
1) Press and hold the density adjustment key for 5 sec to start
setting.
When
lamps start blinking at the same time,
the copy quantity display shows "--" the digit of 10 blinking.
2) Select the function code with the numeric key.
The code of the selected function is displayed (blinking) on the
digits of 10 and 100.
For auto clear, select 1.
Select the suitable code according to the table below.
User program setting contents
Function Function code Setting code
Auto clear 1 0 (Cancel)
1 (30 sec)
2 (60 sec)
3 (90 sec)
4 (120 sec)
Pre-heat 2 0 (Cancel)
1 (30 sec)
2 (60 sec)
3 (90 sec)
4 (120 sec)
Auto power shut off passing
time (*2)
3 1 (30 sec)
2 (60 sec)
3 (90 sec)
4 (120 sec)
5 (240 sec)
Stream feeding mode 4 0 (Cancel)
1 (Setting)
Auto power shut off function
setting (*2)
5 0 (Cancel)
1 (Setting)
2 in 1/4 in 1 solid frame setting 6 0 (Cancel)
1 (Setting)
Rotation copy 7 0 (Cancel)
1 (Setting)
Paper auto selection 8 0 (Cancel)
1 (Setting)
Tray auto selection 9 0 (Cancel)
1 (Setting)
Department counter (*1) 10 ~ 15
Edge erase 16 0 (0mm)
1 (5mm)
2 (10mm)
3 (15mm)
4 (20mm)
2 in 1 layout (*3) 17 1 (Pattern A)
2 (Pattern B)
4 in 1 layout (*3) 18 1 (Pattern A)
2 (Pattern B)
3 (Pattern B)
4 (Pattern B)
Setting at the factory shipping
*1. For the setting procedure, refer to "3. Department counter."
*2. With the auto power shut off canceled (function code "5", set
code "0", auto power shut off time setting code "3"), the mode
enters the auto power shut off setting mode automatically.
*3. For the layout pattern, refer to page 9-1.
The number of the selected function blinks on the digit of 1 or
the copy quantity display.
Cancel: When any key is pressed by mistake, press the clear key
and press the proper key.
3) Press the START key.
The selected function code is changed from blinking to lighting.
The currently set code blinks on the digit of 1.
4) Select the setting code with the numeric key.
For setting to 80 sec, select 3.
Make setting referring to the setting codes of "User program
setting contents."
Cancel: When any wrong key is pressed, press the clear key and
resume from procedure 2.
5) Press the START key,
The selected setting code is changed from blinking to lighting.
The setting is completed with the above operation.
Memo: To set another function, press the clear key after this proce-
dure and resume from procedure 2.
6) Press the density adjustment key to end the setting.
lamps go off. The copy quantity display
returns to the normal display.
3. Department counter setting
Note: The department counter is effective only in copying. Counting
is not made in FAX and printer output.
When the department counter is set, the copy count for each depart-
ment (max. 20 dept.) can be made and displayed when necessary.
With the department counter set, copying cannot be made unless the
registered number (password number of 3 digits) is entered.
1) Press and hold the density adjustment key for about 5 sec to
start setting.
lamps start blinking at the same time, and
the copy quantity display displays "--" and the digit of 10 blinks.
2) Select the function code with the numeric key.
Refer to the function code for setting.
Setting contents of department counters
Function Function code
Setting content 10 Department counter
setting or cancel. Factory
setting: Cancel
Department
counter
setting/cancel
11 Department number
recording.
Max. 20 department can
be recorded.
Department
number recording
12 Recorded department
number is changed.
Department
number delete
13 Recorded number is
deleted.
Copy quantity
display (Total)
14 The copy quantity in each
department is displayed.
The count is made up to
49,999 sheets. From that,
counting is started from 0.
Copy quantity
delete (Total
delete)
15 The counted copy quantity
is canceled. The count of
each department or that of
all the departments can be
deleted.
The entered number blinks on the digits of 100 and 10 on the
copy quantity display.
Cancel: When a wrong key is pressed, press the clear key and enter
the correct key.
AR-161
AR-160/161 FM/E [9] USER PROGRAM 11/27/1998
9 – 2