Smart Technologies 800ixe-SMP Whiteboard Accessories User Manual


 
Projector
Power light
Projector
Service light
ACP light Ready light
Projected
image
Touch and
pen control
Status and related
troubleshooting
Solidamber Flashingred N/A N/A None N/A There’s anissuewiththeprojector
lamp.
SeeThe“LampFailure”message
appears onpage60.
Off Flashingred Solidamber Off None None Theprojector’soperatingtemperature
has beenexceeded.
SeeThe“ProjectorOverheated”,“Fan
Failure”or“ColorWheelFailure”
messageappears onpage59.
Off Solidred N/A N/A None N/A There’sanissuewiththeprojector’s
fanorcolorwheel.
SeeThe“ProjectorOverheated”,“Fan
Failure”or“ColorWheelFailure”
messageappears onpage59.
Off Off Off Off None None Theprojectorpowercableisn’t
properly connected.
OR
TheACPpowersupply isn’t properly
connected.
OR
There’s anissuewiththemains
powersupply (forexample, thecircuit
breakeris off).
Resolving interactive whiteboard issues
This section includes information on resolving issues with your interactive whiteboard.
For information not covered in this section, see the SMARTBoard 800 series interactive whiteboard
user’s guide (smarttech.com/kb/144817).
Resolving operation issues
To resolve operation issues, complete the following tasks:
l Confirm that the camera system cable is connected to the back of the pen tray.
l Perform the calibration procedure documented in the SMARTBoard 800 series interactive
whiteboard user’s guide (smarttech.com/kb/144817).
l If necessary, complete additional troubleshooting with the guidance of SMARTSupport using
SMARTBoard Diagnostics.
C HA PTER 7
Troubleshootingyour interactivewhiteboardsystem
57