SRS Labs CP-X809 Projector User Manual


 
47
OPTION menu
OPTION menu (continued)
Item Description
SERVICE
(continued)
FANSPEED
Using the ▲/▼ buttons switches the rotation speed
of the cooling fans. The HIGH is the mode for use at
highlands etc. Note that the projector is noisier when
the HIGH is selected.
HIGH
NORMAL
AUTO ADJUST
Using the ▲/▼ buttons to select one of the mode.
When the DISABLE is selected, the automatic
adjustment feature is disabled.
FINE
FAST
DISABLE
FINE: Finer tuning including H.SIZE adjustment.
FAST:
Faster tuning, setting H.SIZE to prearranged data for the input signal.
Depending on conditions, such as input image, signal cable to the projector,
environment around the projector, etc., the automatic adjustment may not
work correctly. In such a case, please choose DISABLE to disable the
automatic adjustment, and make adjustment manually.
GHOST
1.
Select a color element of ghost using the
◄/►
buttons.
2.
Adjust the selected element using the ▲/▼ buttons to
disappear ghost.
FILTER MESSAGE
Use the ▲/▼ button to set the timer for the interval to
show the message for cleaning up the air filter.
500h
1000h
1500h
2000h
TURN OFF
After choosing an item except TURN OFF, the message
“REMINDER *** HRS PASSED AFTER THE LAST FILTER
CHECK” will appear after the timer reaches the interval time
set by this feature
(
70)
.
When the TURN OFF is chosen, the message will not appear.
Utilize this feature to keep the air filter clean, setting the suitable time according
to your environment of this projector.
• Please check and clean the air filter periodically, even if there is no
message. If the air filter becomes to be blocked by dust or others,
the internal temperature will rise, which could cause malfunction, or
reduce the lifetime of the projector.
Please be careful with the operating environment of the projector
and the condition of the air filter.
• This setting has an influence on the keystone distortion etc.
• About the optional lens, ask you dealer.
LENS TYPE
Select the lens type currently used using the
▲/▼
buttons.
1
2
3
4
5
Please select one of them referring to the following.
1: for a standard lens (Type NL-600)
2: for a fixed short throw lens (Type FL-601)
3: for a short throw lens (Type SL-602)
4: for a long throw lens (Type LL-603)
5: for an ultra long throw lens (Type UL-604)