6.5 Voltage Regulation
STATUS
Required
The power supply output voltages must stay within the following voltage limits when operating at steady state and
dynamic loading conditions. These limits include the peak-peak ripple/noise specified in Section 5.8. All outputs
are measured with reference to the return remote sense (ReturnS) signal. The 5 V, 12V1, 12V2, 12V3, –12 V and
5 VSB outputs are measured at the power supply connectors referenced to ReturnS. The +3.3 V is measured at
its remote sense signal (3.3VS) located at the signal connector.
Table 18: Voltage Regulation Limits
Parameter MIN NOM MAX Units Tolerance
+3.3 V +3.20 +3.30 +3.46 V
rms
+5/-3%
+5 V +4.80 +5.00 +5.25 V
rms
+5/-4%
+12V1 +11.52 +12.00 +12.60 V
rms
+5/-4%
+12V2 +11.52 +12.00 +12.60 V
rms
+5/-4%
+12V3 +11.52 +12.00 +12.60 V
rms
+5/-4%
-12 V -11.40 -12.20 -13.08 V
rms
+9/-5%
+5 VSB +4.85 +5.00 +5.25 V
rms
+5/-3%
STATUS
Optional
Some system applications may require tighter regulation limits on the +5 V output. The optional regulation limits
are shown below.
Table 19: Optional +5V Regulation Limits
Parameter MIN NOM MAX Units Tolerance
+5 V +4.85 +5.00 +5.25 V
rms
+5/-3%