SSI America EPS2U Power Supply User Manual


 
SSI
EPS2U Power Supply Design Guide, V2.1
8.3.2 FRU Data Format
The information to be contained in the FRU device is shown in the following table.
Table 30: FRU Device Information
Area Type Description
Common Header As defined by the FRU document
Internal Use Area Not required, do not reserve
Chassis Info Area Not applicable, do not reserve
Board Info Area Not applicable, do not reserve
8.3.2.1 Product Info Area
Implement as defined by the IPMI FRU document. Product information shall be defined as follows:
Table 31: FRU Device Product Information Area
Field Name Field Description
Manufacturer Name {Formal name of manufacturer}
Product Name {Manufacturer’s model number}
Product part/model number Customer part number
Product Version Customer current revision
Product Serial Number {Defined at time of manufacture}
Asset Tag {Not used, code is zero length byte}
FRU File ID {Not required}
PAD Bytes {Added as necessary to allow for 8-byte offset to next area}
- 28 -