SSI
EPS2U Power Supply Design Guide, V2.1
9 MTBF
STATUS
Recommended
The power supply shall have a minimum MTBF at continuous operation of 1) 50,000 hours at 100% load and
45 °C, as calculated by Bellcore RPP, or 2) 100,000 hours demonstrated at 100% load and 50 °C.
10 Agency Requirements
STATUS
Recommended
The power supply must comply with all regulatory requirements for its intended geographical market. Depending
on the chosen market, regulatory requirements may vary. Although a power supply can be designed for
worldwide compliance, there may be cost factors that drive different versions of supplies for different
geographically targeted markets.
This specification requires that the power supply meet all regulatory requirements for the intended market at the
time of manufacturing. Typically this includes:
• UL
• CSA
• A Nordic CENELEC
• TUV
• VDE
• CISPR Class B
• FCC Class B
The power supply, when installed in the system, shall meet immunity requirements specified in EN55024.
Specific tests are to be EN61000-4-2, -3, -4, -5, -6, -8, -11, EN61000-3-2, -3, and JEIDI MITI standard. The
power supply must maintain normal performance within specified limits. This testing must be completed by the
system EMI engineer. Conformance must be designated with the European Union CE Marking. Specific
immunity level requirements are left to customer requirements.
- 30 -