Initiating and Terminating Tests from the Modem’s Front Panel
To initiate a test from the modem’s front panel:
1) Press until you reach the TEST OPTS category.
2) Press until you reach Test=End Test.
3) Press until Test=LAL (for example)
4) Press to start the test.
To terminate a test from the modem’s front panel:
1) Press until Test=End Test.
2) Press to stop the test.
Synchronous Data Compression (SDC) Testing
When performing diagnostic tests in SDC mode, note the following:
All tests are supported
When initiating the following online tests:
Remote digital loopback
Remote digital loopback pattern
Data mode pattern
Local digital loopback
during SDC connection, the modem falls back to Direct mode (Mode=Direct,
AT
*
SM) to run the test. If the modem is set for internal timing
(Clock=Internal, AT&X) the DTE clock is changed to match the DCE rate. If
the modem is set for external timing (Clock=External, AT&X), the clock rate
provided may not match the DCE rate and the test will not function. (Set
Clock=Internal temporarily to complete testing, and then reset to External.)
To test the synchronous data paths integrity while running loopback tests, set
the modem for one of the asynchronous buffered modes (Mode=Normal,
Reliable, Auto Reliable, or Speed Auto Reliable).