Telenetics V.32bis Series Network Router User Manual


 
Configuration Quick Reference A-3
Configuration
Quick-Reference
Figure A-1. The 326X Series Modem Menu Structure - Part 1 of 4
KEY
Country Specific
Option
Option Included
in Option Sets
==
(A)
(D)
(1-4)
(L)
(d)
(S)
(F)
(†)
Default for All Option Sets
Default for Options Not Included in Option Sets
Default for Option Set
n
(
n
=1-4)
Option Set Default for 3261, 3263, 3266, 3268 Modems
Option Set Default for 3260, 3262, 3265, 3267 Modems
Default for 326X V.32bis Modem
Default for 326X
FA ST
Modem
Available with 326X
FA S T
Only
=
=
=
=
(SDC) = Sync Data Compression (available for 326X
FAST-
SDC only)
For example, in the Min Rate (AT
*
MN) option,
:9600 (2,3,4L SDC) means 9600 is the default for option sets
2, 3 and 4L (models 3261
FA ST
, 3263
FA ST
, 3266
FA ST
and 3268
FAST
) with the Sync Data Compression product.
Otherwise, the default is 300 bps for all option sets.
=
=
=
=
TEST OPT'S
Mod=V.34 Auto (A,F)
MODULATION OPT'S Line=Dial (1,2,3,4d)
:2W Lease (4L)
:4W Lease
:V.34 Only
:V32bis Auto (A,S)
:Auto V32
:V32bis Only
:V32 Only
:V32 Uncoded
:V22bis Only
:212 Only
:103 Only
:V21 Only
Low Speed=Bell
:CCITT
Max Rate=14.4(S)/28.8 (A,F)
Auto Type=CCITT (A)
:Codex
:33.6
:31.2
:21.6
:19.2
:16.8
:14.4 (A,S)
:12.0
:9600
:7200
:4800
:2400
Min Rate=300 (A)
AdaptiveRate=On (A)
Retrain=High BER
Longspace=Off (A)
Mode=Originate (1,3) Clock=Internal (A)
:1200
:2400
:4800
:7200
:9600 (2,3,4L SDC)
:12.0
:14.4
:16.8
:19.2
:21.6
:24.0
:Off :Answer (2,4)
:External
:Auto A in O
:External (2 SDC)
:Loopback
:Off
:Low BER
:On
Fast Call=Off (A)
:Lvl1
:Lvl2
:Lv i3 (2,3,4L SDC)
PSTN=On (A)
:Off
:550
:1800
Guard Tone=Off
AT & L AT
*
MM AT
*
AY AT
*
LS AT
*
MX AT
*
MN AT
*
FC
AT
*
AP AT
*
CA AT&X
AT
*
RT ATY AT
*
MD
AT & G
V.34 Asym=On
:Off
AT
*
AR
RESTORAL OPT'S Restore=Off (1,2,3,4d)
LtoD=Low/Fast (A)
D to L=Manual (1,2,3,4d)
Hold Dialine=Off (A) Ans Rest=LL Fail (A)
:FP Only
:FP/108.1
:FP/116
:FP/Auto (4L)
:FP/108.ACU
:FP/116.ACU
:Low/Slow
:High/Fast
:High/Slow
:15 min
:30 min
:1 hour
:2 hour
:4 hour
:1 min
:2 min
:3 min
:4 min
:5 min (4L SDC)
:Always
AT
*
RE AT
*
DI AT
*
LE AT
*
HD AT
*
AS
Data (DCE Rate) T/D?
Pressing at this
display toggles modem
between talk/data
states
Save Changes=1
:2
:3
:4
Power Up In=Old (D)
:1
:2
:3
:4
Reinit Memory?
Dial From#=1
:n
:9
View Phone#=1
:n
:9
Link Phone#=1
:n
:9
Enter Then Dial
Select Options=1
:2
:3
:4
Accept RDL=On
TEST=End Test
LAL Busy Out=On
:Off
Enter Phone#=1
:n
:9
:LAL
:RDL
:LDL
:Pattern
:LAL Pat
:RDL Pat
:Busy Out
:Retrain
:Off
S-Reg nnn=xxx
AT Z AT& W AT & Y
AT DS
AT
*
DS
AT
*
ND
AT& Z
AT
*
CN
AT & F
AT
*
DR
AT &T
AT & T
AT H
AT O
AT
*
LL
AT D
AT S
AT
*
LN
Auto Redial=Off (D)
:1
:n
:15
PhaseJitter=0dg
Frq Offset=0Hz
Tx Level=0dbm
Rx Level=-0dbm
Retrains 0
Echo Delay=0ms
Far Echo Lvl=0
Nr Echo Lvl=0
Phase Roll=0
Eqlzr SNR=0dB
SQ=0 EP=0%
DTE (Rate) EC Mode
EC=(Mode)DC=(Mode)
Tx Kb 0%
Rx Kb 0%
DCD RTS CTS
DSR DTR
AOP DLP ALP
DR=0 TI=0 O D
Display Modem ID
(s/w rev lvl)
ATI
AT & V
AT
*
ST
AT & V
AT
*
ST
Rx =
nnnn
Tx =
mmmm
:1200
:300
:26.4
:28.8
:26.4
:24.0
:31.2
:33.6
Note:
When you select Modulation Mode
(AT*MM), you must ensure that the
Max Rate (AT*MX) and Min Rate
(AT*MR) parameter options are within