~ In the case of QR code (Two-dimensional code)
Format c [ESC] XBaa; bbbb, cccc, d, e, ff, g, h (, Mi) (, Kj) (, Jkkllmm) (= nnn --- nnn) [LF] [NUL]
d [ESC] XBaa; bbbb, cccc, d, e, ff, g, h (, Mi) (, Kj) (, Jkkllmm) (; oo
1
, oo
2
, oo
3
------ oo
20
)
[LF] [NUL]
Term aa: Bar code number
00 to 31
bbbb: Print origin of X-coordinate of the bar code
Fixed as 4 digits (in 0.1 mm units)
cccc: Print origin of Y-coordinate of the bar code
4 or 5 digits (in 0.1 mm units)
d: Type of bar code
T: QR code (Two-dimensional code)
e: Designation of error correction level
L: High density level
M: Standard level
Q: Reliability level
H: High reliability level
ff: 1-cell width
00 to 52 (in dots)
g: Selection of mode
M: Manual mode
A: Automatic mode
h: Rotational angle of the bar code
0: 0°
1: 90°
2: 180°
3: 270°
Mi: Selection of model
(Omissible. If omitted, Model 1 is automatically selected.)
i = 1: Model 1
2: Model 2
Kj: Mask number
(Omissible. If omitted, the number is automatically set.)
j = 0 to 7: Mask number 0 to 7
8: No mask
Jkkllmm: Connection setting
(Omissible. No connection if this parameter is omitted.)
kk = 01 to 16: Value indicating which divided code is connected.
ll = 01 to 16: Number of divided codes
mm = 00 to FF: A value for all data to be printed, to which XOR is applied
in units of bytes (Not divided)
nnn --- nnn: Data string to be printed (Omissible)
Max. 2000 digits
oo
1
--- oo
20
: Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 digits can be designated using commas.