Toshiba BSX4TGS20QMR Printer User Manual


 
- 114 -
f: User block password read/write permanent lock designation (Effective to
Bank4 to Bank8 only)
0: Disabled
1: Enabled
NOTES:
1. Once a permanent lock is enabled for parameter b, d, or f, any
subsequent change is disabled.
2. When read/write permanent lock is selected, a read/write lock state is
retained. To permanently prohibit reading/writing a tag, enable both
the read/write lock and the read/write permanent lock. The setting
which disables read/write lock and enables read/write permanent lock
allows the tag to be read/written permanently.
Xghhhhhhhh: User block access password execution setting (Effective only when the
Hibiki tag is used for the B-SX704-RFID-U2-R.)
Designates a password to access and write a tag of which user block is
write-locked.
Up to five user blocks can be specified continuously.
For example: X4AABBCCDD,X5BBCCDDEE,X6CCDDEEFF
g: Designates a user area bank. (4 to 8)
4: Bank4 (User block 1)
5: Bank5 (User block 2)
6: Bank6 (User block 3)
7: Bank7 (User block 4)
8: Bank8 (User block 5)
hhhhhhhh: User block access password
Fixed to 8-digit hexadecimal number
00000000 to FFFFFFFF
uvvvvvvvvvv: Increment/Decrement
(Omissible. When omitted, incrementing/decrementing is not performed.)
u: Indicates whether to increment or decrement
+: Increment
-: Decrement
vvvvvvvvvv: Skip value (10 digits)
0000000000 to 9999999999
www---www: Print data string (Omissible)
Max. 512 digits, but the number of digits to be written is different depending
on the tag types.
ww
1
,ww
2
,ww
3
,-----,ww
20
: Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.