Toshiba TECRA M4 Personal Computer User Manual


 
4 Replacement Procedure 4.32 Fluorescent lamp
Removing the cell with PCB
1. Remove the cell with PCB from the backlight unit as shown bellow.
2. Completely remove the double-sided tape remaining on the reverse side of the cell.
CAUTION: 1. A portion of the upper side of cell is adhered to the frame with the
double-sided tape. Remove the cell gently, taking care not to damage it.
2. Do not remove the ray-shield tape on the upper, lower, right and left of
face and back of cell.
3. Be careful not to damage the FPC.
Ray-shield tape on the back
Remove cell
while removing
double sided tape.
Ray-shield tape on the back
Ray-shield tape
on the back
Ray-shield tape
on the back
Figure 4-53 Replacing 14.1 Inch TMD fluorescent lamp (5)
4-82 [CONFIDENTIAL] TECRA M4 Maintenance Manual (960-521)