Ultimate Technology 500 POS Mouse User Manual


 
13
Table 2. Local Mode Programming Function Codes and Default Settings
11 MSR Channel 1,3 Field
Separator
^ (5Eh) for
format 1
= (3Dh) for
format 3
Used to send a field separator between
fields of the magnetic card channel.
12 MSR Channel 1,3 Suffix ?<CR>
(3Fh,0Dh)
for both
format 1 and
3
Used to send suffixes after the
magnetic card channels.
13 MSR Channel 3 Account
Separator
: (3Ah) for
format 3
Used to send an account separator on
the magnetic card channel.
14 MSR Channel 2 Prefix ; (3Bh) for
format 2
Used to send a prefix after the
magnetic card channel.
15 MSR Channel 2 Field Separator = (3Dh) for
format 2
Used to send a field separator between
fields of the magnetic card channel.
16 MSR Channel 2 Suffix ?<CR>
(3Fh,0Dh)
for format 2
Used to send a suffix after the
magnetic card channel.
17 MSR Bad Read Track 1,3 M1!<CR>
(4Dh,31h,21
h,
0Dh)
Used to send a key sequence to the
host computer upon a bad magnetic
card read.
18 MSR Bad Read Track 2 M2!<CR>
(4Dh,32h,21
h,
0Dh)
Used to send a key sequence to the
host computer upon a bad magnetic
card read.
19 MSR Sending Send any
track
Used to send MSR data if one or both
tracks are good.
0 = send any track; 1 = send if both
tracks are good.
20 RS232 Port 0 Baud Rate 9600 Baud
Rate
Used to select a baud rate for Port 0.
Baud rates available are: 300, 600,
1200, 2400, 4800, 9600, 19200, 38400
and 57600.
21 RS232 Port 0 Stop Bits 2 stop bits Used to select number of stop bits, 1
or 2, used with Port 0.
22 RS232 Port 0 Parity No parity
Used to select parity used with Port 0.
Selections available are: no parity, odd
parity or even parity.
23 RS232 Port 0 Handshaking Both Used to select method of handshaking used
with Port 0. Selections available are: none,
CTS/RTS, XON/XOFF or both.