24
Table 3. Local Mode Programming Instructions - Continued
Note: *Default Settings
Function Code(s) Operation Normal Indication Remarks
21 or 31
Main Port 0 (21)
AUX Port 1 (31)
Stop Bits
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 21 (Port 0) or 31 (Port 1).
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the number of stop bits (1 or 2) per
list below.
1 = one stop bit
2 = two stop bits*
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.
22 or 32
Main Port 0 (22)
AUX Port 1 (32)
Parity
1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function
Code 22 (Port 0) or 32 (Port 1).
LED (2) turns on.
2. At Series 500 Keyboard numeric keypad, enter the applicable number (0, 1 or 2) to
select type of parity per list below.
0 = none*
1 = odd
2 = even
LED (2) turns off.
3. Program the next function code or exit programming mode by entering 99 on Series
500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.