NOTE • Although bright spots or dark spots may appear on the screen, this is a unique char-
acteristic of liquid crystal displays, and such do not constitute or imply a machine defect.
Phenomenon Cases not involving a machine defect Reference page
No pictures are
displayed.
The lens cover is closed.
Remove the lens cover.
Part name
Power on/off
The signal cables are not correctly connected.
Correctly connect the connection cables.
Connecting your devices
The brightness is adjusted to an extremely low
level.
Adjust the BRIGHT to a higher level using the
menu function or the remote control.
EASY MENU
PICTURE menu
Colors have a
faded-out
appearance, or
Color tone is
poor.
Color settings are not correctly adjusted.
Perform picture adjustments by changing the
COLOR TINT, COLOR TEMP and/or COLOR
SPACE settings, using the menu functions.
EASY MENU
PICTURE menu
INPUT menu
COLOR SPACE setting is not suitable.
Change the COLOR SPACE setting to AUTO,
RGB, SMPTE240, REC709 or REC601.
INPUT menu
Pictures appear
dark.
The brightness and/or contrast are adjusted to
an extremely low level.
Adjust the BRIGHT and/or CONTRAST settings to
a higher level using the menu function.
EASY MENU
PICTURE menu
The WHISPER function is working.
Select the NORMAL to the item WHISPER in the
SETUP menu.
EASY MENU
SETUP menu
The lamp is approaching the end of its product
lifetime.
Replace the lamp.
Lamp
Pictures appear
blurry.
Either the focus and/or horizontal phase set-
tings are not properly.
Adjust the focus using the focus ring, and/or H
PHASE using the menu function.
Adjusting the zoom and
focus IMAGE menu
The lens is dirty or misty.
Clean the lens by referring to the section “Other
care”.
Other care