Xantrex Technology XDI2048 Power Supply User Manual


 
AC Load and Signal Line Connection
TM-DIOP-01XN-01 2-13
CAN/SYNC Connector
Overview
The CAN/SYNC connector provides access to functions necessary for
operation of multiple units in parallel, series or three phase. The
connector is a 7-position wire clamp adjacent to the user-line. Two sets of
signals are provided on this connector:
Can-bus: Paralleled units relay data necessary to achieve load sharing
between units using this arbitration bus. The protocol used is
proprietary hence cannot be and should not be interfaced to different
products.
Sync-lines: Used to configure and synchronize units in parallel, series
or 3 phase.
Specifications:
CAN/SYNC Connection
Table 2-2 outlines the pinout of the terminal. See connection schemes for
wiring method applicable to your requirements.
Maximum number of units 10
Bus Speed 1 Mb/sec
Termination 120 1/4 W
Addresses 1 to 10