50 • Making copies XEROX WIDE FORMAT COPY SYSTEM
Some documents will always exit to the rear at the completion of the
scan regardless of the DOCUMENT RETURN setting. These documents
include:
• Thick documents
• Documents longer than 5 feet (1.52 meters)
• Documents over 36 inches (914 mm) in width
MODE:
MANUAL - The user must enter the width of the document manually, and
very carefully center the document when inserting it into the Scan
System. The document is prescanned in this mode.
AUTOWIDTH - This is the default setting. When AUTOWIDTH is
selected, the Scan System automatically detects the width of the
document.
AUTOWIDTH/AUTOCENTER - The document is prescanned in this
mode. When AUTOWIDTH/AUTOCENTER is enabled, the Scan System
automatically centers the image and automatically detects the document
width.
PRODUCTIVITY – ANSI - PRODUCTIVITY is only available on Scan
Systems with FreeFlow Accxes firmware 10.0 or higher, Scan System
firmware 3.2.6 or higher, and the Productivity Document Feed Tray that
includes discrete width sensors. PRODUCTIVITY – ANSI is the default.
Other media type selections include ARCH, ISO A, ISO B, JIS B and
CUSTOM. These selections must be made so that the sensors detect
the correct width. This feature eliminates the prescan width
measurement, which increases document throughput speed resulting in
greater productivity. CUSTOM requires standard media sizes to be
entered in CUSTOM MEDIA FORMATS.
AUTOWIDTH and AUTOWITH/AUTOCENTER are not available in this
mode.
Select the Menu key > CONFIGURATION>SCAN SYSTEM CONTROL,
MODE: for additional information.