Fuse Replacement
A user-replaceable AC power fuse is located just below the AC power switch at the
rear of the printer. The replacement fuse is a 3AG fast blow style rated at
5 Amp/250 VAC.
Before replacing the fuse, turn off the AC power switch and unplug the AC power
cord.
To replace the fuse, insert the tip of a flat blade screwdriver into the slot in the end of
the fuse holder end cap. Press in slightly on the end cap and turn the screwdriver
slightly counterclockwise. This will disengage the end cap from the fuse holder and
permit removal of the fuse.
To install a new fuse, reverse the sequence.