Zebra Technologies R110PAX4 Printer Accessories User Manual


 
129
Print Engine Diagnostics
6/29/11 110PAX4/R110PAX4 User Guide 57512L-004
Communications Diagnostics Test
The communication diagnostics test is a troubleshooting tool for checking the interconnection
between the print engine and the host computer.
When the printer is in diagnostics mode, it prints all data received from the host computer as
straight ASCII characters with the hex values below the ASCII text. The print engine prints all
characters received, including control codes such as CR (carriage return). Figure 31 shows a
typical test label from this test.
Figure 31 • Communications Diagnostics Test Label
To use communications diagnostics mode, complete these steps:
1. Set the print width equal to or less than the label width being used for the test. See Set
Print Width on page 67 for more information.
2. Set the printer to DIAGNOSTICS. For instructions, see Set Communications Mode
on page 80.
The printer enters diagnostics mode and prints any data received from the host computer
on a test label
3. Check the test label for error codes. For any errors, check that your communication
parameters are correct.
Errors show on the test label as follows:
FE indicates a framing error.
OE indicates an overrun error.
PE indicates a parity error.
NE indicates noise.
4. Turn the print engine off (O) and then back on (I) to exit this self test and return to normal
operation.
Note • The test label prints upside-down.